How to Replace a Reverse Osmosis Water Tank: The Easy Way Done Right
In another video I showed how I re-pressurized the tank on my reverse osmosis system. Everything was good, then I went away for a few days and came back to a stream that starts off and just fades out. After a few days it didn’t work, and that’s an indication you need a new tank. Mine is an APEC system, but the principle is the same for other units.
This is my DIY replacement on my system. Follow your system’s instructions, follow at your own risk, and use proper safety precautions.
Before You Begin: Getting the Right Tank
I checked Amazon first, but they didn’t have the APEC tank at the time, so I went direct to APEC for a 4-gallon tank (the label actually says 4.8). Interestingly, it doesn’t say APEC on it. It’s a model RO132. Mine even arrived with a ding in it, so check yours when it comes. My old tank was dated 2020, and I’m replacing it in 2025, so it lasted five years.
Tanks & Tools
Disclosure: Some of the links below are affiliate links. As an Amazon Associate, I earn from qualifying purchases. If you choose to buy through them, it helps support my work at no additional cost to you.
- APEC Water Systems Tank-4, 4 gallon https://amzn.to/4814Sgt
- tankRo RO132-TNK 4 gallon RO expansion tank (NSF certified) https://amzn.to/3Ja92K4
- iSpring T55M 5.5 gallon pre-pressurized storage tank https://amzn.to/4mBLU5M
- Teflon tape
- A tire pump (to push the water out of the old tank) and a pressure gauge
Step 1: Turn Off the Water Supply
Under the sink, turn off the water supply to the RO system first.
Step 2: Disconnect the Tank Line and Release the Pressure
Disconnect the yellow supply pipe for the tank. It comes from a T connection: excess water goes into the tank, and when you turn on the faucet it comes out of the faucet. With the tank valve off, release the pressure. On these push-fit fittings, you push the collar in and pull the tube out. Then lift out the tank. It’s heavy when it’s full, and mine was rusted on the bottom.
Step 3: Drain the Old Tank
When you make the change you have to get rid of the old tank and dispose of the water. I used the pipe that goes to the RO unit to drain it, and pumped air in with a tire pump, which forced the water out pretty well.
Tip: I found out afterwards that you can simply tip the tank upside down and the water comes out. That’s a lot easier than messing around with the pump.
Step 4: Move the Tank Valve to the New Tank
I took the valve off the old tank and put it on the new one. Perhaps I should have bought a new valve, but I figured this one was still good. Wrap the threads with Teflon tape (I did about two and a half turns) and make sure it feels nice and snug.
When you put the tank back under the sink, face the air valve so you can get at it later to top up the air pressure.
Step 5: Check the Air Pressure
I couldn’t find my standalone gauge, so I used the pressure gauge on the pump, which should be pretty accurate. The new tank read 6.3. From what I heard in several videos, between five and seven is about the optimum for the APEC system. Other systems specify something different, so check yours.
Step 6: Reconnect and Turn the Water Back On
Put the tank in place and push the yellow pipe back into the tank valve and the RO unit. Turn the water supply back on, which starts the filters again. It takes time for the tank to fill. Check that there are no leaks.
Step 7: Flush the First Tank
After a couple of hours, I ran out the first batch of water to clean out the new tank. The stream was strong, and the tank was holding a good amount of water. Throw that first tankful out, and use the next one for drinking.
Final Thoughts
If your RO faucet starts strong and fades out even after you’ve re-pressurized the tank, a new tank is an easy swap. While you’re under the sink, see how I changed all 5 APEC RO filters, and here’s my video on fixing RO tank pressure.