How to Replace a Water Heater T&P Valve the Right Way (My Mistakes)
I tested the temperature and pressure relief (T&P) valve on my water heater, and then it wouldn’t stop leaking. I tried opening and closing it and every trick to re-seat it, but nothing worked, so I shut off the water and ordered a new valve. This tank is about 9 years old and the original valve had never been replaced.
The T&P valve is a critical safety device, so take this one seriously. This is my experience on my heater. Follow your manufacturer’s instructions, follow at your own risk, and call a plumber if you’re unsure.
Before You Begin: Get the Right Valve
Match the pressure and temperature ratings. My new valve is rated 150 psi and 210°F, which are the ratings I needed. Please confirm the valve fits your water heater before buying. This is the one I used:
Disclosure: Some of the links below are affiliate links. As an Amazon Associate, I earn from qualifying purchases. If you choose to buy through them, it helps support my work at no additional cost to you.
- T&P valve I used (by ProTech) https://amzn.to/4fop1Ct
Tools You’ll Need
- New T&P valve with the correct ratings (mine came with thread tape already on)
- Wrench to remove the discharge pipe and valve
- Hose or container for draining the tank
- Something to clean out the valve port
- An empty bucket for testing the new valve
Step 1: Turn Off the Water and Set the Control to Pilot
Turn off the cold water supply, and set the gas control to the pilot position so the heater won’t fire while you work.
Step 2: Drain the Tank Below the Valve
The water level has to be below the T&P valve. I let some drain from the tank drain at the bottom. My mistake: I didn’t drain enough, and when I pulled the valve, water started coming out. I put it back in, drained more (another full container), and tried again.
Step 3: Remove the Discharge Pipe and Old Valve
Take off the discharge pipe first, then unscrew the old valve. Mine was covered with mineral deposits inside and out, which would certainly clog it up. A valve in that condition might stick and not do its job in a high-pressure or high-temperature event.
Step 4: Clean the Valve Port
Before installing the new one, look inside the port. I found deposits in there too and cleaned out what I could.
Step 5: Install the New T&P Valve
Screw in the new valve, then turn it so the outlet points in a good position for the discharge pipe. I gave it about another turn to make sure it was firmly in place. Then reconnect the discharge pipe.
Step 6: Refill and Leak Test
Turn the water back on to refill the tank and check for leaks. I tested the new valve to make sure it releases. It took a while to close again, so have an empty bucket under the discharge pipe when you test it.
Step 7: Restart and Bleed the Air
Turn the gas back on, then go to a faucet upstairs to get the air out of the system.
Final Thoughts
Testing an old T&P valve can make it fail, so be ready to replace it. Either way, it’s a wear item and an important maintenance job you shouldn’t ignore. If you need to empty the tank completely, see my video on draining a water heater tank.